CUMMINS 160KW Diesel Generator Set for landuse

CUMMINS 160kw Diesel Engine Generator Set from China
CUMMINS 160KW Diesel Generator Set  for Landuse

Engine of CUMMINS E160GL Diesel Generator Set for Landuse

Engine model DCEC CUMMINS 6CTAA8.3-G2
No. of cylinders 6(in-line)
Displacement(L) 8.9
Induction system Exhaust turbocharged,   air-air inter-cooling
Combustion system    P7100 pump,GAC electrical governor
Bore*Stroke(mm) 114*135
Compression ratio 16.6:1
Rated speed(rpm) 1500
Maximum power(KW/HP) 240/326
speed control system  High precision electrical speed governor
exhaust smoke level(m3/min) 35
Exhaust temperature(°C) 470
Maxium exhaust back pressure(kPa) 10.1
Maxium intake pressure(kPa) 6.2
Air consumption(m3/min) 13
Air flow(m3/min) 326
100% load fuel consumption(L/H) 45
The total capacity of oil(L) 23.8
Oil consumption(g/kwh) ≤4
Oil sump capacity(L) 24
Rated oil pressure(kPa) 276-414
Coolant capacity (engine and radiator)(L) 24
Thermostat opening temperature(°C) 82-93
Maximum water temperature(°C) 104
   

Alternator of CUMMINS E160GL Diesel Generator Set for Landuse

Alternator model(Stamford) UCI274H
Alternator model(Marathon) MP-160-4
Alternator model(Engga) EG280M-160N
Phase 3
Winding connection 4 wire 3 phase ,Y type 
Starter battery capacity(Ah) 165*2
Starter battery voltage(V) 24
No. of bearings 1
Power factor 0.8
Protection class IP23
Altitude requirement(m) ≤1000
Excitation mothod Brushless 
Insulation class /temperature class H/H
Steady-state voltage reguation ≤±1%
Alternator capacity 250KVA
Alternator efficiency 0.927
Cooling air flow(m3/s) 0.58
voltage regulate range ≥±5%
Steady-state voltage reguation ≤±1%
Transient voltage deviation(100% sudden power reduction) ≤+25%
Transient voltage deviation(sudden power incremen) ≤-20%
Voltage stabilization time (100% sudden power reduction)(S) ≤6
Voltage stabilization time (sudden power increment) (S) ≤6
Steady-state frequency regulation ≤5%adjustable
Frequency volatility ≤0.5%
Transient frequency deviation (100% sudden power reduction) ≤+12%
Transient frequency deviation (sudden power increment) ≤-10%
Frequency recovery time(100% sudden power reduction)(S) ≤5
Frequency recovery time (sudden power increment)(S) ≤5
   

CUMMINS E160GLDiesel Generator Set for Landuse 

Model E160GL
Continous output(50Hz) 160/200KVA
Standby output(50Hz) 180/225KVA
Rated frequency(Hz) 50/60
Open type external dimension of base fuel tank(mm) 2400*970*1580
Net weight(kg) 1750
Silent type external dimension(mm) 3590*1250*2050
Weight(kg) 2900

Welcome to contact us for more information of  CUMMINS 160kw Diesel Generator Set for Landuse .
Quick search:  CUMMINS Generator Set ( 20KW  30KW  45KW  75KW  90KW  100KW  110KW  120KW  140KW   200KW  220KW  250KW  280KW  300KW  330KW  360KW  400KW  420KW  500KW  800KW  1000KW)  for Landuse.